Description
48FCEM08A2A5-0A0A0 Carrier WeatherMaker – 7.5 Ton Packaged Rooftop Gas Heat & Electric Cool Unit R-410A (208/230-3-60) – E:Mail: sales@walkair.us to confirm availability or for volume discounts
48FCEM08A2A5-0A0A0
48 = Gas Heat Packaged Rooftop / Unit Heat Type
FC = Standard Efficiency (EcoBlue™ Technology) / Model Series – WeatherMaker®
E = Medium Heat / Heat Size
M = Single Circuit, Two Stage Cooling / Refrig. Systems Options
08 = 7.5 Tons / Cooling Tons
A = None / Sensor Options
2 = Standard/Medium Static Option / Indoor Fan Options
A = Al/Cu – Al/Cu / Coil Options – (Outdoor – Indoor)
5 = 208-230/3/60 / Voltage
– = Factory Design Revision / Design Revision
0 = Electro-mechanical Controls – can be used with field-installed W7212 EconoMi$er® IV (Non-Fault Detection and Diagnostic) / Base Unit Controls
A = None / Intake / Exhaust Options
0 = None / Service Options
A = None / Electrical Options
0 = Standard / Packaging & Seismic Compliance
The New Carrier WeatherMaker® rooftop units (RTU) with EcoBlue™ Technology were designed by
| Attributes | |
|---|---|
| Air Flow Direction | Convertible |
| Approvals | UL Listed |
| BTU Input | 120,000-180,000 |
| BTU Output | 98,000-148,000 |
| Blower Motor HP | 2 2/5 BHP |
| Blower Motor RPM | 250-2,000 |
| Blower Motor Speeds | Variable |
| Blower Motor Type | ECM (Electronically Commutated Motor) |
| Blower Wheel Diameter | 22″ |
| Brand | Carrier® |
| CFM | 1,350-3,750 |
| Color | Gray |
| Compressor Type | Scroll |
| Condenser Coil Fins per Inch (FPI) | 18 |
| Condenser Fan Blade Diameter | 22 |
| Condenser Fan Motor Qty | 2 |
| Condenser Motor HP | 1/4 |
| Condenser Motor RPM | 1,100 |
| Condenser Motor Speeds | 1 |
| Condenser Motor Type | PSC (Permanent Split Capacitor) |
| Cooling Capacity | 86,000 |
| Cooling Rated Capacity (Btu/h) | 90000 |
| Country of Origin | MEX |
| Cubic Measurement | 125.1689 |
| Cycle/Hertz | 60 Hz |
| Drain Connection Size | 3/4″ |
| Drive Type | Direct |
| EER | 11.2 |
| Energy Star Rated | NO |
| Evaporator Coil Fins per Inch (FPI) | 15 |
| Evaporator Coil Metering Device | TXV/TEV – Thermostatic Expansion Valve |
| Fuel Type | Natural Gas |
| Gas Connection Size | 3/4″ |
| Gas Connection Type | NPT |
| IEER | 15 |
| Locked Rotor Amps (LRA) | 123 |
| Maximum Overcurrent Protection (MOCP) | 50 |
| OPT Code | 1P48FCEM08A2A5-0A0A0 |
| Outdoor Air Filter Size (OA) in Inches (W x H x D) | 20 x 24 x 1 |
| Phase | Three |
| Product Family | 48FC |
| Prop 65 | YES |
| Rated Load Amps (RLA) | 13.1 |
| Refrigerant | R-410A |
| Return Air Filter Size (RA) in Inches (W x H x D) | (4) 16 x 20 x 2 |
| Sound Level (dBA) | 79 |
| Stages Cooling | 2 |
| Stages Heating | 2 |
| Thermal Efficiency | 82% |
| Tier | WeatherMaker® |
| Tonnage | 7.5 |
| UPC | See Optical |
| Voltage | 208-230 VAC |