Description
COMPACT SOLUTION FOR LOW AIRFLOW VELOCITIES
Rectangular air terminal units for use in variable air terminal systems at low air velocities, even under unfavorable upstream conditions
- Tubeless differential pressure measurement via damper blade
- Differential pressure transmission through differential pressure duct in axis
- Connection terminals with protective cover, no junction box required
- Any airflow direction if dynamic transducer is used
- Suitable for air velocities from 158 – 1575 ft/min
- Compact dimensions for use in confined ceiling areas
- Plug-and-play solution in conjunction with X-AIRCONTROL room control
- Exact measurement even with low airflow velocities
- Any installation orientation also with static transducer
- Closed blade air leakage to EN 1751, at least class 3
- Casing air leakage to EN 1751, class C
- Volume flow rate range 1:10
Optional equipment and accessories
- Secondary silencer to reduce air-regenerated noise
- Hot water heat exchanger Type WT for reheating the airflow
Application
- Square VAV terminal units for use in ventilation and air conditioning systems (AHUs)
- For almost all tasks when controlling, restricting, or shutting off supply and extract air flows
- Also for unfavourable upstream conditions at low air velocities
- Closed-loop volume flow control using an external power supply
- For variable or constant volume flow systems
- Shut-off by override control (by the client)
Special characteristics
- High differential pressure signal with small angle of attack
- Factory set-up or programming and aerodynamic function testing
- Volume flow rate can be measured and subsequently adjusted.
- Additional adjustment tool may be required (depending on the variant of the control component)
- Tubeless differential pressure measurement via damper blade
- Differential pressure transmission through differential pressure duct in axis
- Any airflow direction if dynamic transducer is used
- Any installation orientation also with static transducer
- Suitable for air velocities from 158 – 1575 ft/min
- Compact dimensions for use in confined ceiling areas
Nominal sizes
- 8″ x 4″, 12″ x 4″
- 8″ x 8″, 12″ x 8″, 16″ x 8″, 20″ x 8″, 24″ x 8″
Variants
- TVE-Q: VAV terminal unit
- TVE-Q with TX secondary silencer to reduce air-regenerated noise
Construction
- Galvanised sheet steel
- P1: Powder-coated, silver grey (RAL 7001)
Parts and characteristics
- Ready-to-commission unit which consists of mechanical parts and control components.
- Damper blade with integrated measuring unit
- Axis with differential pressure duct for measured value transmission
- Control component factory mounted
- Each unit is tested on a special aerodynamic test rig at the factory
- Documentation of the test rig data with a test label or a volume flow scale on the unit
- High control accuracy even in case of unfavourable upstream conditions
Attachments
- EASY controller: compact unit consisting of controller with potentiometers, differential pressure transducer and actuator
- Compact controller: compact unit consisting of controller, differential pressure transducer and actuator
- Compact controller: with Modbus RTU interface and display; plug-and-play solution in conjunction with X-AIRCONTROL room control system
Useful additions
- Secondary silencer Type TX for the reduction of airregenerated noise
- Hot water heat exchanger Type WT for reheating the airflow
Construction features
- Rectangular casing
- Flanges on both ends, suitable for duct connections
- Position of the damper blade indicated externally at position indicator
- Simple exchange of the control components possible
Material and surfaces
Galvanised sheet steel
- Casing, damper blade made of galvanised sheet steel
- Shaft made of PA6 (H ≤ 200) or aluminium (H > 200)
- Damper blade seal and sealing plug made of EPDM
- Bearing bushes made of PBT or TPU
- Fastening (screws, rivets) Galvanised steel, aluminium
Powder-coated construction (P1)
- Casing, damper blade galvanised with powder coating, RAL 7001, silver-grey
- Shaft made of PA6 (H ≤ 200) or aluminium (H > 200)
- Damper blade seal and sealing plug made of EPDM
- Bearing bushes made of PBT or TPU
- Fastening (screws, rivets) stainless steel, aluminium
Standards and guidelines
Meets the hygiene requirements of
- EN 16798, Part 3
- VDI 6022, Sheet 1
- DIN 1946, Part 4
- For further standards and guidelines please refer to the hygiene certificate
Casing leakage
- EN 1751, Class C
Closed damper blade air leakage:
NS 200×100, NS 300×100, NS 200×200
- EN 1751, Class 2
NS 300×200, NS 400×200, NS 500×200, NS 600×200
- EN 1751, Class 3
Maintenance
- Maintenance-free as construction and materials are not subject to wear and tear
Literature
- Product Brochure
- Product IOM
- TVE Sales Flyer
- Installation and commissioning instructions Easy Controller