Description
916SA30026M14 Bryant Legacy – 96% AFUE 26000 BTUH Multipoise ECM Condensing Gas Furnace – E:Mail: sales@walkair.us to confirm availability or for volume discounts
916SA30026M14
9 = 90+% / Heat Exchanger
1 = Legacy Line / Tier/NOx
6 = 96% / AFUE/NOx
S = Single Stage / Heating Stages
A = Major Series
30 = 1000 CFM / Cooling Capacity (CFM)
026 = 26,000 BTU/h / Heat Input
M = Multi 18-Speed Constant Torque (MCT) ECM / Motor Type
14 = 14.2″ / Width
The 916SA Multipoise Condensing Gas Furnace features the single-stage Legacy™ System. The fixed-speeds, constant torque (MCT) ECM blower motor is at the heart of the electrical efficiency provided by this furnace. With an Annual Fuel Utilization Efficiency (AFUE) of 96.2% AFUE, this furnace provides added savings over standard gas furnaces. Improved serviceability with the 3 digit status display and NFC enabled board allowing setup via the service tech app. This Legacy Gas Furnace features 4-way multipoise installation flexibility, and is available in model eleven sizes. All sizes except the 26,000 BTUh model can be vented for direct vent/two-pipe, ventilated combustion air, or single-pipe applications. The 26,000 BTUh model can use the same 2-pipe venting system using outside air for combustion, but is not considered direct-vent. A Bryant Legacy Control and Legacy Air Conditioner or Heat Pump, can be used to form a complete Legacy Line System. All sizes are design certified in Canada. Specific sizes are design certified for use in Manufactured Housing (Mobile Home) applications when used with factory-approved MH accessory kit.
PERFORMANCE
- Multi 18-speed, constant torque (MCT) ECM blower motor for electrically efficient operation all year long in heating, cooling and continuous fan operation.
- Enhanced diagnostics with easy to read 3-digit display for faults and status.
- Single-speed inducer motor, and single-stage gas valve.
- Silicon Nitride PerfectLight™ Hot Surface Igniter.
- Perfect Humidity® technology removes more moisture than a standard furnace during cooling operation (when installed with a matched air conditioner or heat pump)
- Adjustable blower speed for heating and cooling.
- Aluminized-steel primary heat exchanger.
- Stainless-steel condensing secondary heat exchanger.
INSTALLATION FLEXIBILITY
- On-board NFC antenna makes setup a tap away when using the Bryant service technician app.
- 4-way multipoise design for upflow, downflow or horizontal installation, with unique vent elbow for optional venting through-the-cabinet downflow venting capability.
- Factory-configured ready for upflow applications.
- Ideal height 35” (889 mm) cabinet: short enough for taller coils, but still allows enough room for service.
- Two-pipe venting, single-pipe venting or ventilated combustion air.
APPLICATIONS
- Approved for Twinning applications with accessory kit (48060M17, 048080M17, 060080M21, 60100M21, 66120M24, 66140M24 models, only).
- Approved for Manufactured Housing/Mobile Home applications with MH accessory kit.
- Convertible to propane with gas conversion accessory kit.
CERTIFICATIONS
- All sizes meet ENERGY STAR® Version 4.1 criteria for gas furnaces: 95%+ AFUE.
- Cabinet air leakage less than 2.0% at 1.0 in. w.c. and cabinet air leakage less than 1.4% at 0.5 in. w.c. when tested in accordance with ASHRAE standard 193.
- All sizes can be installed in air quality management districts with a 40 ng/J NOx emissions requirements.
| Attributes | |
|---|---|
| AFUE | 95-96 |
| Air Flow Direction | Multi-Position |
| BTU Input | 26,000 |
| BTU Output | 25,000 |
| Blower Motor HP | 1/3 |
| Blower Motor Speeds | 18 (Eighteen) |
| Blower Motor Type | ECM (Electronically Commutated Motor) |
| Brand | Bryant® |
| CFM | 175-970 |
| CFM Heating | 620 |
| Cabinet Width | 14.1875 |
| Color | Beige |
| Country of Origin | No Longer Available |
| Cubic Measurement | 8.4772 |
| Cycle/Hertz | 60 Hz |
| Energy Star Rated | Yes |
| FER Compliant | No |
| Filter Size | 16″ x 25″ x 3/4″ |
| Fuel Type | Natural Gas or LP |
| Full Load Amps | 4.4 |
| Furnace Type | Gas |
| Gas Connection Size | 1/2″ |
| Gas Connection Type | NPT |
| Ignition Type | Hot Surface (HSI) |
| Includes Filter Rack | No |
| Maximum Overcurrent Protection (MOCP) | 15 |
| Phase | Single |
| Product Family | 916SA |
| Prop 65 | Yes |
| Stages Heating | (1) Single |
| Voltage | 115 VAC |